Map Recent Data Charts Control Radar Alarms Notes Maintenance Contact ☰

To carry out maintenance, use the Android app.

This page is for reading and downloading what has already been recorded. The visit itself is done on a phone at the site, offline, and uploaded on the trip or afterwards (depending on cell service).

Download the app

‹ all sites

Gordon 3

2026-09-06 10:27

Group
CoG
Site
Gordon 3
Data file
Gordon_3.csv
Started
2026-09-06 10:27:25
Ended
2026-09-06 10:29:03
Times
phone local time UTC-04:00
Rows
33

The record

TimeEventItemValueUnit PointStandardNote
10:27:25 visit started Gordon 3 CoG
10:27:25 method chosen DTEC — depth mrcm
10:27:25 job added by hand DTEC — depth not in this site's data
10:27:25 method chosen DTEC — temperature clean
10:27:25 job added by hand DTEC — temperature not in this site's data
10:27:25 method chosen Turbidity — NTU ccc
10:27:25 job added by hand Turbidity — NTU not in this site's data
10:27:25 method chosen Battery maintenance swap
10:27:30 site check Radar — no rainfall ok
10:27:31 site check Access — safe and stable ok
10:27:32 site check No damage in work area ok
10:27:34 taken out of order the site and safety checks skipped the wide site shot
10:27:48 depth-pressure step Manual depth invert to water surface 22 mm 1 22 before the clean
10:27:52 dtec probe Probe lifted out of the water done
10:27:53 depth-pressure step Probe body cleaned done 1
10:27:53 temp step Probe body and temperature bead wiped done
10:27:54 dtec probe Probe returned to the water at the same height done
10:27:59 depth-pressure step Manual depth after replacing 22 mm 1 22 after the clean
10:28:02 taken out of order dtec left unfinished skipped the close-up before you touch it
10:28:02 depth-pressure step Sensor-reported depth at that moment 26 mm 1 22 before the clean
10:28:02 depth-pressure step Sensor-reported depth after replacing 26 mm 1 22 after the clean
10:28:33 turb probe Sensor removed from the mount done
10:28:40 turbidity cleaned sensor cleaned done the second pass begins here
10:28:48 turbidity remounted sensor rinsed and returned to its mount done
10:28:50 taken out of order Sensor remounted in the same position skipped the readings above are not done
10:28:51 turb probe Sensor remounted in the same position done
10:28:53 taken out of order turb left unfinished skipped the close-up before you touch it; point 1 has no standard value; point 1 missing 4 readings before the clean; point 1 missing 4 readings after the clean; point 2 has no standard value; point 2 missing 4 readings before the clean; point 2 missing 4 readings after the clean
10:28:54 battery step Batteries changed done
10:28:54 batteries changed battery pack changed
10:28:59 final check battery 3600 mV fail
10:28:59 final check last logged 2 min ago pass
10:29:02 taken out of order ending the visit skipped DTEC — depth is not finished; DTEC — temperature is not finished; Turbidity — NTU is not finished; the final check did not pass; closing close-ups for 2 probes; the closing wide shot
10:29:03 visit ended Gordon 3